{"product_id":"40833gt-40833-275a-fast-acting-fuse-genie","title":"40833GT 40833 275A Fast-Acting Fuse CNN-275A for Genie GS GR QS TZ Lifts | SAIYIS","description":"\u003cdiv style=\"font-family:Arial,sans-serif;color:#374151;line-height:1.6;\"\u003e\n\u003cp\u003eThis \u003cstrong\u003e40833GT \/ 40833 275A fast-acting fuse\u003c\/strong\u003e is an aftermarket replacement for matching electrical protection circuits on compatible Genie lifts. Internal specification reference: \u003cstrong\u003eCNN-275A\u003c\/strong\u003e. Supplied as one fuse for maintenance replacement or fleet spare stock.\u003c\/p\u003e\n\u003ch3 style=\"margin:20px 0 10px;padding:0;font-size:16px;font-weight:bold;background:none;\"\u003eCompatible Models — Supplier Application References\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 16px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eVertical mast lifts\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eGR-08, GR-12, GR-15, GR-20, GRC-12, QS-12R, QS-12W, QS-15R, QS-15W, QS-20R, QS-20W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eScissor lifts\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eGS-1432m, GS-1530, GS-1532, GS-1930, GS-1932, GS-1932m, GS-2032, GS-2046, GS-2632, GS-2646, GS-2646AV, GS-2646AV35, GS-2668DC, GS-3232, GS-3246, GS-3268DC, GS-4046, GS-4047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eTrailer-mounted boom lifts\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eTMZ-34\/19, TMZ-50\/30, TZ-34\/20, TZ-50\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eDesigned as an aftermarket replacement for compatible configurations of the models listed above. These applications are supplier-listed references, not confirmation for every production year. Verify the original part number and machine serial number before ordering.\u003c\/p\u003e\n\u003ch3 style=\"margin:20px 0 10px;padding:0;font-size:16px;font-weight:bold;background:none;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:0 0 16px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eReplacement part numbers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e40833GT, 40833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSpecification reference\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCNN-275A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCurrent rating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e275 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eFuse characteristic\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eFast-acting; verify the required time-current characteristic against the original fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eVoltage application reference\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eSupplier lists 48V. Confirm the actual supplied fuse DC voltage rating against its marking and machine requirements before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCompatible make\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eGenie\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eNew Aftermarket (OEM-Grade Quality)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003ePackage contents\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e1 × replacement fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCNN275 dimensional benchmark, L × W × H\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e81 × 16.3 × 10.2 mm (3.19 × 0.64 × 0.40 in); Mersen reference design, not verified measurements of this aftermarket unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eCNN275 weight benchmark\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e0.0272 kg (0.060 lb); Mersen reference design only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003eEstimated packed shipping weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;text-align:left;\"\u003e0.10 kg (0.22 lb); provisional estimate, verify before dispatch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eCNN-type products from different manufacturers can have different voltage ratings and operating characteristics. The reference dimensions and weight above are for comparison only and do not establish Mersen manufacture, certification or interchangeability. Confirm terminal spacing, mounting dimensions, DC voltage rating, interrupting capacity and fuse speed against the original part before fitting.\u003c\/p\u003e\n\u003cp\u003eDisconnect and isolate the battery before service. Have a qualified technician diagnose the cause of a blown fuse before replacement. Never bypass the fuse or substitute a higher current rating to mask an electrical fault.\u003c\/p\u003e\n\u003cdiv style=\"background:#fffbeb;border-left:4px solid #f5a623;padding:12px 16px;margin:20px 0;\"\u003eNeed help matching your fuse or purchasing fleet spares? Send the fuse marking, mounting photos and machine serial number to \u003ca href=\"mailto:support@awp-parts.com\"\u003esupport@awp-parts.com\u003c\/a\u003e. SAIYIS Support Team can assist with matching and bulk inquiries.\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#6b7280;\"\u003eSAIYIS is an independent aftermarket parts supplier. This is not a genuine Genie product. Manufacturer names and part numbers are used for identification and compatibility reference only.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SAIYIS","offers":[{"title":"1PC","offer_id":67903093178477,"sku":"04.35.009","price":35.0,"currency_code":"USD","in_stock":true},{"title":"2PCS","offer_id":67903093211245,"sku":"04.35.0010","price":59.0,"currency_code":"USD","in_stock":true},{"title":"4PCS","offer_id":67903093244013,"sku":"04.35.0011","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0717\/5834\/8397\/files\/01-saiyis-40833gt-genie-275a-control-circuit-fuse-main.jpg?v=1793327280","url":"https:\/\/www.awp-parts.com\/fr\/products\/40833gt-40833-275a-fast-acting-fuse-genie","provider":"SAIYIS AWP Parts","version":"1.0","type":"link"}