You release the lift control, but the hydraulic pump motor continues running.
The platform may stop moving while the motor keeps operating, or the machine may continue making the familiar pump-motor sound even though no lift command is being requested.
This is not the same problem as a hydraulic pump motor that runs but cannot raise the platform.
In this situation, the important question is why the electric motor continues receiving power after the operator's command should have ended.
Possible causes include:
- A sticking lift switch or joystick input
- A control circuit that continues requesting lift
- A contactor with welded or stuck contacts
- A faulty relay or controller output
- Damaged or shorted control wiring
- A machine-specific automatic function or control sequence
This guide explains how to separate an unwanted lift command from a motor power-circuit fault before replacing expensive components.
Safety warning: A pump motor that runs unexpectedly can overheat, create abnormal hydraulic pressure, or cause unintended machine behavior depending on the hydraulic circuit. Stop using the machine, keep personnel clear of hazardous areas, and follow the manufacturer's shutdown and electrical isolation procedures. Electrical testing of high-current motor circuits should be performed by qualified technicians.
First Confirm What Is Actually Running
Not every humming, clicking, or buzzing sound near a hydraulic power unit means the pump motor is running.
Depending on the machine, the sound could come from:
- The hydraulic pump motor
- A contactor or relay
- A solenoid coil
- Another powered component
Before replacing anything, determine which component is producing the sound.
A qualified technician can use the correct service documentation and diagnostic information to identify whether the motor is actually energized.
Do not touch rotating parts or open energized high-current enclosures to locate the source of the noise.
Normal Motor Operation vs Abnormal Continuous Running
On many electric scissor lifts, the hydraulic pump motor operates when a function requires hydraulic power.
Once the relevant command ends, the motor should stop according to the machine's control logic.
However, some machines have additional automatic functions or control sequences. Do not assume that every brief period of motor operation after a control change is abnormal.
Compare the observed behavior with the specific machine's operator and service manuals.
Continuous running outside the intended operating sequence requires investigation.
Understand the Two Sides of Pump Motor Control

A useful way to understand this fault is to divide the electrical system into two sections:
1. The Command Circuit
The command circuit determines when the hydraulic pump motor should operate.
Depending on machine design, that request may originate from:
- Platform control switch
- Joystick or enable input
- Ground control station
- Electronic control module
The command may then pass through safety and machine-control logic before activating the motor power circuit.
2. The Motor Power Circuit
The motor power circuit delivers electrical energy to the pump motor.
Depending on machine design, the circuit may include a contactor, relay, or electronic power-control device.
This distinction creates two very different failure possibilities:
Unwanted command: The control system continues requesting motor operation.
Power circuit remains closed: The control request has ended, but the motor still receives power.
These conditions require different repairs.
Can a Stuck Lift Switch Keep the Pump Running?
Yes, depending on the control design.
A mechanically damaged or electrically failed lift switch may continue sending a lift request after the operator releases it.
Potential symptoms include:
- The switch does not return normally
- The switch feels loose, sticky, or damaged
- The pump continues running after the control is released
- The symptom changes when the control moves
However, a normally returning switch does not prove that its electrical contacts are working correctly.
The input must be evaluated according to the applicable electrical schematic.
Can the Joystick Cause the Same Problem?
On machines where a joystick or integrated platform control provides the lift request, an input fault can potentially affect motor operation.
Possible causes include:
- Damaged internal switch
- Incorrect input signal
- Faulty enable control
- Connector or cable problem
The joystick should not automatically be replaced simply because the motor continues running.
The technician must first determine whether the control system is still receiving an active command.
For a broader explanation of joystick problems, see our Aerial Lift Joystick Troubleshooting Guide.
A Stuck Motor Contactor Is an Important Possibility

Many DC-powered machines use an electromechanical contactor to connect battery power to a high-current electric motor.
When the contactor is energized, its main contacts close and allow current to reach the motor.
When the contactor is released, the contacts should open as designed.
Over time, electrical or mechanical damage can prevent contacts from opening correctly.
One possible condition is welded contacts, where contact surfaces remain electrically connected even after the operating coil is no longer commanded.
Depending on the electrical architecture, the motor may then continue receiving power.
Important: Not every scissor lift uses a separate pump-motor contactor. Some designs use other motor-control arrangements. Confirm the actual machine circuit before looking for a contactor.
Why Contactor Contacts Can Become Damaged
Contactors are designed for specific electrical loads and switching conditions.
Problems may develop because of:
- Contact wear
- Excessive electrical arcing
- Abnormal motor current
- Incorrect replacement component
- Mechanical damage
- Operating conditions outside the component's rating
A damaged contactor may require replacement, but its failure cause should also be considered.
Replacing the contactor without investigating abnormal current or a damaged motor circuit may allow another failure to occur.
Motor Contactor vs Control Relay: What Is the Difference?
A relay and a contactor both use controlled electrical switching, but they are not automatically interchangeable.
A motor contactor is typically designed to switch higher-current loads such as electric motors.
A smaller control relay may switch control signals or intermediate circuits.
Depending on the machine, a control relay may activate the contactor rather than powering the pump motor directly.
This matters because a faulty relay can potentially keep the contactor energized, while welded main contactor contacts can keep motor power connected even after the relay releases.
The appropriate component can only be identified from the exact electrical diagram.
Do Not Diagnose a Contactor From Clicking Alone
A contactor click indicates mechanical movement or an attempt to operate.
It does not confirm that the main power contacts are opening and closing electrically as intended.
Possible faults include:
- Contacts that fail to close
- Contacts that remain closed
- Damaged coil
- Loose terminals
- Internal mechanical wear
Use the manufacturer's specified electrical testing method rather than relying on sound.
A Controller Output Can Keep the Motor Circuit Active
On electronically controlled scissor lifts, the pump motor may be operated through a controller output or an intermediate switching device.
If that output remains active unexpectedly, the motor-control device may continue operating.
Possible areas requiring diagnosis include:
- Controller input status
- Controller output status
- Related safety inputs
- Control-module supply voltage
- External wiring
Do not assume a faulty controller without verifying its inputs and the components connected to its output.
See our Aerial Lift Motor Controller Guide for more on the differences between controllers, motors, and related electronic components.
Damaged Wiring Can Create an Unwanted Command
Electrical wiring can be damaged by abrasion, vibration, moisture, or previous repairs.
Depending on the circuit design, certain wiring faults may cause an input or output to remain in an active state.
Inspect the relevant control wiring for:
- Damaged insulation
- Incorrect previous splices
- Loose connections
- Corroded connectors
- Crushed or pinched cable sections
Do not randomly disconnect wires from an operating machine to determine whether the pump stops.
Use an approved isolation and diagnostic procedure.
What if the Pump Runs From Both Control Stations?
Some machines allow hydraulic functions to be requested from both platform and ground controls.
If the motor continues running regardless of which station was used, the technician should consider whether the problem is located in a shared motor-control circuit.
However, that observation does not prove a specific component is faulty.
The control-station selection and electrical logic vary between machines.
What if It Happens Only From Platform Controls?
If the abnormal motor operation is associated with platform control input but not the corresponding ground command, the platform-side circuitry deserves closer investigation.
Possible areas include:
- Platform lift input
- Control box
- Joystick
- Platform harness
- Control connector
Use the working control station as a comparison only where the manufacturer's service procedure permits.
What if the Motor Runs but the Platform Does Not Move?
A pump motor can continue operating even when the platform remains stationary.
This does not necessarily mean hydraulic pressure is being delivered to the lift cylinder.
Possible explanations may involve the hydraulic valve arrangement, the absence of an appropriate lift command, or another hydraulic condition.
In this article, however, the first priority is to determine why the motor remains electrically energized.
Hydraulic testing should be performed only after the machine has been made safe and the electrical control problem has been addressed.
Why Continuous Motor Operation Can Cause Additional Damage
Hydraulic pump motors are designed to operate within specified electrical and duty-cycle limits.
Unexpected continuous operation may contribute to:
- Motor overheating
- Excessive battery discharge
- Electrical connection heating
- Hydraulic fluid heating
- Additional wear or damage
Depending on the hydraulic circuit, continuous pump operation against a restricted path may also generate excessive heat.
Do not continue operating the machine simply to observe how long the motor will run.
Is the Pump Motor Itself the Problem?
A motor that continues rotating because it is receiving electrical power is not necessarily defective.
The motor may be doing exactly what the energized power circuit is commanding it to do.
Before ordering a replacement DC motor, the technician should determine whether the problem originates in the control input or the electrical switching circuit.
A new motor will not repair welded contactor contacts or an unwanted controller command.
Is the Hydraulic Pump the Problem?
The hydraulic pump converts motor rotation into hydraulic flow.
It does not normally determine whether an electric motor should remain energized.
Therefore, when the specific problem is that the motor continues running after the control is released, focus first on the electrical control and power circuit.
For pump identification and compatibility information, see our Hydraulic Pump Replacement Guide.
A Practical Troubleshooting Checklist
The following checklist describes a diagnostic framework, not instructions to test a live high-current circuit.
1. Stop operating the machine.
Follow the manufacturer-approved shutdown and isolation procedure.
2. Confirm the component producing the sound.
Determine whether the pump motor is actually running.
3. Record the circumstances.
Identify which control was used, when the motor began running, and whether platform movement stopped.
4. Identify the motor-control architecture.
Locate the relevant switches, relays, contactors, or electronic outputs in the correct schematic.
5. Evaluate the lift-command input.
Determine whether the control system continues requesting motor operation.
6. Evaluate the power-switching device.
Check whether it is operating according to the service procedure.
7. Inspect associated wiring.
Check for damaged connectors, wiring, or previous repairs.
8. Confirm the repair.
Complete the required electrical, hydraulic, and machine functional checks before returning the equipment to service.
How to Identify the Correct Replacement Component
When a switch, contactor, relay, or controller has been confirmed faulty, verify its compatibility before ordering.
Important information may include:
- Machine manufacturer
- Exact model
- Complete serial number
- OEM part number
- Electrical ratings
- Terminal arrangement
- Connector type
- Mounting configuration
- Hardware or software version where applicable
Electrical switching components that look identical may have different coil voltages, contact ratings, or terminal functions.
Do not substitute a visually similar component without verifying its suitability for the application.
Frequently Asked Questions
Why does my scissor lift hydraulic pump keep running?
Possible causes include a lift control that remains active, a stuck relay or contactor, a controller output fault, or damaged control wiring. The exact cause depends on the machine's motor-control system.
Can a stuck contactor make the hydraulic pump motor run continuously?
Yes. On applicable machines, damaged or welded power contacts may leave the motor electrically connected after the normal command has ended.
Does a continuously running pump mean I need a new pump?
Not necessarily. If the electric motor is being supplied with power unexpectedly, the problem is more likely related to the control or motor-power circuit than the hydraulic pump itself.
Can a bad joystick keep the pump motor running?
Potentially, if the joystick or integrated control input remains electrically active. The input should be tested rather than automatically replacing the joystick.
Can a relay click normally but still be defective?
Yes. Mechanical clicking does not prove that electrical contacts are switching correctly.
Is it safe to keep using a scissor lift if the pump motor will not stop?
No. Unexpected continuous motor operation requires the equipment to be removed from service until the cause is identified and repaired according to manufacturer procedures.
Final Thoughts
When a scissor lift hydraulic pump motor keeps running after the operator releases the lift control, the most useful diagnostic distinction is:
Is the motor still being commanded to run, or is the motor power circuit remaining connected after the command ends?
These are two different failure paths.
Diagnose the control input, switching device, and related electrical circuit before replacing the hydraulic pump or DC motor.
Correctly identifying the source of unwanted motor operation can prevent unnecessary parts replacement and reduce the risk of additional electrical or hydraulic damage.
Need Replacement Electrical Components for a Scissor Lift?
SAIYIS supplies aftermarket replacement parts for scissor lifts and aerial work platforms, including selected switches, control components, DC motors, joysticks, and related AWP replacement parts.
Before ordering, confirm the failed component and provide the OEM part number, machine model, complete serial number, and clear photographs of the original part and its connections.
Browse available replacement parts at AWP-PARTS.COM.
Manufacturer names and OEM part numbers are used for identification and compatibility purposes only. Electrical diagnosis, repair, and functional testing must follow the appropriate manufacturer documentation.